Wiring Diagrams
Heat Only: Gas or Oil Furnace
Compatible models: All N100
1: COMMON OPTIONAL
2: G USED FOR INDEPENDENT FAN CONTROL ONLY. (MOST HEAT ONLY, GAS OR OIL FORCED AIR SYSTEMS DO NOT USE A FAN [G] WIRE)
Cool Only
Compatible models: All N100
1: COMMON OPTIONAL
Hot Water Boiler, Heat Only
Compatible models: All N100
1: COMMON OPTIONAL
1H/1C: Gas Furnace
Compatible models: All N100
1: COMMON OPTIONAL
2 Transformer System, 1H/1C: Oil Furnace with Air Conditioning
Compatible models: All N100
1: COMMON OPTIONAL
2 Transformer System, Hot Water Heat with Air Conditioning (or Hot Water Coil)
Compatible models: All N100
1: COMMON OPTIONAL
2H/1C: Gas Furnace
Compatible model: TH12320U4002 models only
1: COMMON OPTIONAL
2H/2C: Gas Furnace
Compatible model: TH12320U4002 models only
1: COMMON OPTIONAL
Hot Water Heat with Power Open Zone Valve
Compatible models: All N100
1: COMMON OPTIONAL TO THERMOSTAT
Hot Water Heat with Power Open/Power Closed Series 20 Zone Valve
Compatible models: All N100
1: COMMON OPTIONAL TO THERMOSTAT
2: THERMOSTAT MUST BE CONFIGURED FOR RADIANT HEAT WITH 0 (ZERO) COOL STAGES
1H/1C: Heat Pump without Aux Heat
Compatible models: All N100
1: COMMON OPTIONAL
2: L ONLY CONNECTED IF HEAT PUMP HAS A FAULT TERMINAL
3: SOME HEAT PUMPS USE B RATHER THAN O FOR REVERSING VALVE
4: IMPORTANT: DO NOT CONNECT ANY WIRE TO W FOR HEAT PUMP APPLICATIONS! THIS CAN CAUSE HEAT TO RUN CONTINUOUSLY
2H/1C: Heat Pump with Electric Aux Heat
Compatible model: All TH1320U4002 models only
1: COMMON OPTIONAL
2: L IS ONLY CONNECTED IF HEAT PUMP HAS A FAULT TERMINAL
3: SOME HEAT PUMPS USE B RATHER THAN O FOR REVERSING VALVE
4: DIFFERENT HEAT PUMP MODELS MAY LABEL THE AUXILIARY HEAT TERMINAL DIFFERENTLY THAN SHOWN. CONSULT HEAT PUMP WIRING GUIDE
5: IF LOCKOUT OF AUX HEAT ON HIGH OUTDOOR TEMPERATURE IS REQUIRED, WIRE C7089U1006 TO THE TWO S TERMINALS
6: MOST HEAT PUMPS SHARE THE SAME SET OF HEAT STRIPS FOR AUX AND EM HEAT. IN THESE CASES, E IS NOT USED. MODEL TH1320U4002 CAN BE CONFIGURED FOR SEPARATE AUX AND E. IN THIS SITUATION, WIRE ONE SET OF STRIPS TO E TO BE ENERGIZED IN EM HEAT AND A DIFFERENT SET OF STRIPS TO AUX TO BE ENERGIZED IN AUX HEAT.
7: IMPORTANT: DO NOT CONNECT ANY WIRE TO W FOR HEAT PUMP APPLICATIONS! THIS CAN CAUSE HEAT TO RUN CONTINUOUSLY.
3H/2C: Heat Pump with Electric Aux Heat
Compatible model: TH1320U4002 only
1: COMMON OPTIONAL
2: L IS ONLY CONNECTED IF HEAT PUMP HAS A FAULT TERMINAL
3: SOME HEAT PUMPS USE B RATHER THAN O FOR REVERSING VALVE
4: DIFFERENT HEAT PUMP MODELS MAY LABEL THE AUXILIARY HEAT TERMINAL DIFFERENTLY THAN SHOWN. CONSULT HEAT PUMP WIRING GUIDE
5: IF LOCKOUT OF AUX HEAT ON HIGH OUTDOOR TEMPERATURE IS REQUIRED, WIRE C7089U1006 TO THE TWO S TERMINALS
6: MOST HEAT PUMPS SHARE THE SAME SET OF HEAT STRIPS FOR AUX AND EM HEAT. IN THESE CASES, E IS NOT USED. MODEL TH1320U4002 CAN BE CONFIGURED FOR SEPARATE AUX AND E. IN THIS SITUATION, WIRE ONE SET OF STRIPS TO E TO BE ENERGIZED IN EM HEAT AND A DIFFERENT SET OF STRIPS TO AUX TO BE ENERGIZED IN AUX HEAT.
7: IMPORTANT: DO NOT CONNECT ANY WIRE TO W FOR HEAT PUMP APPLICATIONS! THIS CAN CAUSE HEAT TO RUN CONTINUOUSLY.
Dual Fuel, 2H/1C: Heat Pump
Compatible model: TH1320U4002 only
1: COMMON OPTONAL.
2: L ONLY CONNECTED IF HEAT PUMP HAS A FAULT TERMINAL.
3: SOME HEAT PUMPS USE B RATHER THAN O FOR REVERSING VALVE.
4: THE HEAT PUMP AND FURNACE HAVE SEPARATE BOARDS. THEY ARE SHOWN TOGETHER HERE TO SIMPLIFY THIS DIAGRAM. W IS FROM THE FURNACE BOARD.
5: WIRE C7089U1006 TO THE TWO S TERMINALS.
6: IMPORTANT: DO NOT CONNECT ANY WIRE TO W FOR HEAT PUMP APPLICATIONS! THIS CAN CAUSE HEAT TO RUN CONTINUOUSLY.
Dual Fuel 3H/2C: Heat Pump
Compatible model: TH1320U4002 only
1: COMMON OPTONAL.
2: L ONLY CONNECTED IF HEAT PUMP HAS A FAULT TERMINAL.
3: SOME HEAT PUMPS USE B RATHER THAN O FOR REVERSING VALVE.
4: THE HEAT PUMP AND FURNACE HAVE SEPARATE BOARDS. THEY ARE SHOWN TOGETHER HERE TO SIMPLIFY THIS DIAGRAM. W IS FROM THE FURNACE BOARD.
5: WIRE C7089U1006 TO THE TWO S TERMINALS.
6: IMPORTANT: DO NOT CONNECT ANY WIRE TO W FOR HEAT PUMP APPLICATIONS! THIS CAN CAUSE HEAT TO RUN CONTINUOUSLY.