Installer Setup Options - Heat Pump or PTAC Settings
This does not show all the ISU settings available when Heat Pump or PTAC is selected. These categories are intended to display only the settings specific to those applications. Other settings—such as temperature limits, IAQ control (humidifier, dehumidifier, ventilator), etc.—will be shown for all system types.
|
ISU # |
Heading |
Question |
Options |
Contingent previous setting? |
Notes |
|---|---|---|---|---|---|
|
2000 |
System Type |
System Type |
|
|
It is important that this is set correctly. If you are unsure about what type of system you have contact an HVAC professional to assist. Watch "Identify your heating and cooling system” video. |
|
Equipment type |
|
2000 set to Radiant Heat |
This setting not shown for Heat Pump Applications. Not seeing these settings? Refer to the note at the top of this chart. |
||
|
2060 |
Reversing Valve |
Reversing Valve |
|
2000 set to Heat Pump |
System setup is critical. If you are unsure of this setting, trace the O/B wire from thermostat to the equipment to verify the configuration. O/B wire goes to:
|
|
Compressor Stages |
|
2000 set to Heat Pump |
|
||
|
Backup Heat Stages |
|
2000 set to Heat Pump |
|||
|
2180 |
Backup Heat |
Backup Heat Type |
|
2000 set to Heat Pump and 2070 Backup Heat Stages set to 1. |
The thermostat or app will display different options for this but only supports electric backup. If any other backup heat source is selected it will warn that the thermostat is not compatible and recommend the homeowner contact an HVAC pro to get a compatible model. |
|
3260 |
Temperature Control |
Extended fan run time in cool |
|
At least 1 cool stage |
|
|
Extended fan run time in heat |
At least 1 heat stage |
|
|||
|
4090 |
Temperature Control |
Adaptive Intelligent Recovery |
|
|
When scheduling is used, this feature turns on heat or cooling early to reach the comfort set point by the scheduled comfort time |