Installer Setup Options - IAQ
This does not show all the ISU settings available when IAQ is selected. These categories are intended to display only the settings specific to those applications. Other settings—such as temperature limits, IAQ control (humidifier, dehumidifier, ventilator), etc.—will be shown for all system types.
|
ISU # |
Heading |
Question |
Options |
Contingent previous setting? |
Notes |
|---|---|---|---|---|---|
|
7000 |
Filtration |
Filter type |
|
|
|
|
7110 |
Filtration |
Replacement reminders |
Air Filter 1 settings:
|
7000 = Media |
|
|
|
|||||
|
8000 |
Humidification |
What type of humidifier do you have? |
|
U contacts available |
|
|
8030 |
Humidification |
What terminals are wired to the humidifier? |
|
8000 = other than "none". |
Thermostat U is automatically selected if setup 8000 is set to steam or bypass or fan powered |
|
8100 |
Humidification |
Humidifier Pad replacement reminder |
|
Not shown if 8000 = none or steam |
|
|
8100 |
Humidification |
Clean tank/Water Filter replacement Reminder |
|
8000 = steam |
|
|
9000 |
Dehumidification |
What type of dehumidification equipment do you have? |
|
If AC with High Speed fan is selected, the air-conditioner may cool up to 3 degrees below the cool setpoint when humidity is high |
|
|
9040 |
Dehumidification
|
What terminals are wired to the dehumidification equipment? |
|
Shown when 9000 = Whole House Dehumidifier |
|
|
9210 |
Dehumidification
|
Dehumidifier Filter replacement reminder |
|
|
|
|
10000 |
Ventilation |
Ventilation Type |
|
ERV/HRV or Damper needs available U contacts. |
|
|
10005 |
Ventilation |
Ventilator Model number |
Other model
|
ISU 10000 set to ERV/ HRV |
See Ventilation. |
|
10020 |
Ventilation |
What terminals are wired to the ventilation equipment? |
|
10000 = other than "none". |
|
|
10120 |
Ventilation |
Ventilation Percent On Time |
10% - 100% (30% default) |
1000 = ERV or Fresh Air Damper |
|
|
10170 |
Ventilation |
Ventilation Reminders |
Clean core = Off, 3, 6, 9, 12, calendar months |
Core only shown if 10000 = ERV/HRV. Filter reminder always shown. |
|
|
Clean filter = Off, 3, 6, 9, 12, calendar months |
|
|
|||
|
10200 |
Ventilation |
Ventilate on High Carbon Dioxide (CO2) |
|
10000 = ERV/HRV or Fresh Air Damper S1000 and S1200 models only. |
When enabled, if CO2 levels detected are high, the thermostat will run ventilator and blower fan. Available on models with air quality monitoring only. |
|
11000 |
UV Devices |
Number of UV Devices |
0, 1, 2 |
|
|
|
11050 |
UV Devices |
UV Bulb Replacement Reminders |
Replace UV Bulb 1 = Off, 6, 12, 24 calendar months |
11000 = 1 or 2 |
|
|
Replace UV Bulb 2 = Off, 6, 12, 24 calendar months |
11000 = 2 |
|