Installer Setup Options - IAQ


This does not show all the ISU settings available when IAQ is selected. These categories are intended to display only the settings specific to those applications. Other settings—such as temperature limits, IAQ control (humidifier, dehumidifier, ventilator), etc.—will be shown for all system types.

ISU #

Heading

Question

Options

Contingent previous setting?

Notes

7000

Filtration

Filter type

  • None

  • Media

 

 

7110

Filtration

Replacement reminders

Air Filter 1 settings:

  • Off

  • 10 Run time days

  • 20 Run time days

  • 30 Run time days

  • 45 Run time days

  • 60 Run time days

  • 90 Run time days

  • 120 Run time days

  • 150 Run time days

  • 30 Calendar days

  • 45 Calendar days

  • 60 Calendar days

  • 75 Calendar days

  • 3 Calendar months

  • 4 Calendar months

  • 5 Calendar months

  • 6 Calendar months

  • 9 Calendar months

  • 12 Calendar months

  • 15 Calendar months

7000 = Media

 

 

8000

Humidification

What type of humidifier do you have?

  • None

  • Steam

  • Bypass or Fan powered

U contacts available

 

8030

Humidification

What terminals are wired to the humidifier?

  • Thermostat U

8000 = other than "none".

Thermostat U is automatically selected if setup 8000 is set to steam or bypass or fan powered

8100

Humidification

Humidifier Pad replacement reminder

  • Off

  • 6 or 12 calendar months

Not shown if 8000 = none or steam

 

8100

Humidification

Clean tank/Water Filter replacement Reminder

  • Off

  • 60 or 90 run time days

  • 6 or 12 calendar months

8000 = steam

 

9000

Dehumidification

What type of dehumidification equipment do you have?

  • None

  • AC with High Speed fan

  • Whole House Dehumidifier

If AC with High Speed fan is selected, the air-conditioner may cool up to 3 degrees below the cool setpoint when humidity is high

 

9040

Dehumidification

 

What terminals are wired to the dehumidification equipment?

  • Thermostat U

Shown when 9000 = Whole House Dehumidifier

9210

Dehumidification

 

Dehumidifier Filter replacement reminder

  • Off

  • 30 Calendar Days

  • 60 Calendar Days

  • 3 Calendar Months

  • 4 Calendar Months

  • 5 Calendar Months

  • 6 Calendar Months

  • 7 Calendar Months

  • 8 Calendar Months

  • 9 Calendar Months

  • 10 Calendar Months

  • 11 Calendar Months

  • 12 Calendar Months

 

 

10000

Ventilation

Ventilation Type

  • None

  • ERV/HRV

  • Fresh Air Damper

ERV/HRV or Damper needs available U contacts.

 

10005

Ventilation

Ventilator Model number

Other model

  • VNT5070E1000

  • VNT5200E1000

  • VNT5150E2000

  • VNT5150H2000

  • VNT5200E2000

  • VNT5200H2000

ISU 10000 set to ERV/ HRV

See Ventilation.

10020

Ventilation

What terminals are wired to the ventilation equipment?

  • None

  • Thermostat U

10000 = other than "none".

10120

Ventilation

Ventilation Percent On Time

10% - 100% (30% default)

1000 = ERV or Fresh Air Damper

 

10170

Ventilation

Ventilation Reminders

Clean core = Off, 3, 6, 9, 12, calendar months

Core only shown if 10000 = ERV/HRV. Filter reminder always shown.

 

Clean filter = Off, 3, 6, 9, 12, calendar months

 

 

10200

Ventilation

Ventilate on High Carbon Dioxide (CO2)

  • Yes

  • No

10000 = ERV/HRV or Fresh Air Damper

S1000 and S1200 models only.

When enabled, if CO2 levels detected are high, the thermostat will run ventilator and blower fan.

Available on models with air quality monitoring only.

11000

UV Devices

Number of UV Devices

0, 1, 2

 

 

11050

UV Devices

UV Bulb Replacement Reminders

Replace UV Bulb 1 = Off, 6, 12, 24 calendar months

11000 = 1 or 2

 

Replace UV Bulb 2 = Off, 6, 12, 24 calendar months

11000 = 2