This does not show all the ISU settings available when Reminders is selected. These categories are intended to display only the settings specific to those applications. Other settings—such as temperature limits, IAQ control (humidifier, dehumidifier, ventilator), etc.—will be shown for all system types.
|
ISU # |
Heading |
Question |
Options |
Contingent previous setting? |
Notes |
|---|---|---|---|---|---|
|
7000 |
Filtration |
Filter type |
|
|
|
|
7110 |
Filtration |
Replacement reminders |
Air Filter 1 settings:
|
7000 = Media |
|
|
|
|||||
|
8100 |
Humidification |
Humidifier Pad replacement reminder |
|
Not shown if 8000 = none or steam |
|
|
8100 |
Humidification |
Clean tank/Water Filter replacement Reminder |
|
8000 = steam |
|
|
9210 |
Dehumidification
|
Dehumidifier Filter replacement reminder |
|
|
|
|
10170 |
Ventilation |
Ventilation Reminders |
Clean core = Off, 3, 6, 9, 12, calendar months |
Core only shown if 10000 = ERV/HRV. Filter reminder always shown. |
|
|
Clean filter = Off, 3, 6, 9, 12, calendar months |
|
|
|||
|
10200 |
Ventilation |
Ventilate on High Carbon Dioxide (CO2) |
|
10000 = ERV/HRV or Fresh Air Damper S1000 and S1200 models only. |
When enabled, if CO2 levels detected are high, the thermostat will run ventilator and blower fan. Available on models with air quality monitoring only. |
|
11000 |
UV Devices |
Number of UV Devices |
0, 1, 2 |
|
|
|
11050 |
UV Devices |
UV Bulb Replacement Reminders |
Replace UV Bulb 1 = Off, 6, 12, 24 calendar months |
11000 = 1 or 2 |
|
|
Replace UV Bulb 2 = Off, 6, 12, 24 calendar months |