Wiring Diagrams
Heat Only: Gas or Oil Furnace
Compatible models: All P200 & S200
1: G USED FOR INDEPENDENT FAN CONTROL ONLY. (MOST HEAT ONLY, GAS OR OIL FORCED AIR SYSTEMS DO NOT USE A FAN [G] WIRE)
Cool Only
Compatible models: All P200 & S200
Hot Water Boiler, Heat Only
Compatible models: All P200 & S200
1H/1C: Gas Furnace
Compatible models: All P200 & S200
2 Transformer System, 1H/1C: Oil Furnace with Air Conditioning
Compatible models: All P200 & S200
2 Transformer System, Hot Water Heat with Air Conditioning (or Hot Water Coil)
Compatible models: All P200 & S200
2H/1C: Gas Furnace
Compatible model: TH2320 models only
2H/2C: Gas Furnace
Compatible model: TH2320 models only
Hot Water Heat with Power Open Zone Valve
Compatible models: All P200 & S200
Hot Water Heat with Power Open/Power Closed Series 20 Zone Valve
Compatible models: All P200 & S200
1: THERMOSTAT MUST BE CONFIGURED FOR RADIANT HEAT WITH 0 (ZERO) COOL STAGES
1H/1C: Heat Pump without Aux Heat
Compatible models: All P200 & S200
1: L ONLY CONNECTED IF HEAT PUMP HAS A FAULT TERMINAL
2: SOME HEAT PUMPS USE B RATHER THAN O FOR REVERSING VALVE
3: IMPORTANT: DO NOT CONNECT ANY WIRE TO W FOR HEAT PUMP APPLICATIONS! THIS CAN CAUSE HEAT TO RUN CONTINUOUSLY
2H/1C: Heat Pump with Electric Aux Heat
Compatible models: All TH2320 models only
1: L IS ONLY CONNECTED IF HEAT PUMP HAS A FAULT TERMINAL
2: SOME HEAT PUMPS USE B RATHER THAN O FOR REVERSING VALVE
3: DIFFERENT HEAT PUMP MODELS MAY LABEL THE AUXILIARY HEAT TERMINAL DIFFERENTLY THAN SHOWN. CONSULT HEAT PUMP WIRING GUIDE
4: C7089U1006 WIRED OUTDOOR SENSOR CAN BE USED FOR BALANCE POINT AND AUX HEAT LOCKOUT IF DESIRED
5: MOST HEAT PUMPS SHARE THE SAME SET OF HEAT STRIPS FOR AUX AND EM HEAT. IN THESE CASES, E IS NOT USED. TH2320 MODELS CAN BE CONFIGURED FOR SEPARATE AUX AND E. IN THIS SITUATION, WIRE ONE SET OF STRIPS TO E TO BE ENERGIZED IN EM HEAT AND A DIFFERENT SET OF STRIPS TO AUX TO BE ENERGIZED IN AUX HEAT.
6: IMPORTANT: DO NOT CONNECT ANY WIRE TO W FOR HEAT PUMP APPLICATIONS! THIS CAN CAUSE HEAT TO RUN CONTINUOUSLY.
3H/2C: Heat Pump with Electric Aux Heat
Compatible models: TH2320 models only
1: L ONLY CONNECTED IF HEAT PUMP HAS A FAULT TERMINAL.
2: SOME HEAT PUMPS USE B RATHER THAN O FOR REVERSING VALVE.
3: DIFFERENT HEAT PUMP MODELS LABEL THE AUXILIARY HEAT TERMINAL DIFFERENTLY THAN SHOWN. CONSULT HEAT PUMP WIRING GUIDE.
4: C7089U1006 WIRED OUTDOOR SENSOR CAN BE USED FOR BALANCE POINT AND AUX HEAT LOCKOUT IF DESIRED.
5: MOST HEAT PUMPS SHARE THE SAME SET OF HEAT STRIPS FOR AUX AND EM HEAT. IN THESE CASES, E IS NOT USED. TH2320 MODELS CAN BE CONFIGURED FOR SEPARATE AUX AND E. IN THIS SITUATION, WIRE ONE SET OF STRIPS TO E TO BE ENERGIZED IN EM HEAT AND A DIFFERENT SET OF STRIPS TO AUX TO BE ENERGIZED IN AUX HEAT.
6: IMPORTANT: DO NOT CONNECT ANY WIRE TO W FOR HEAT PUMP APPLICATIONS! THIS CAN CAUSE HEAT TO RUN CONTINUOUSLY.
Dual Fuel, 2H/1C: Heat Pump
Compatible models: TH2320 models only
1: L ONLY CONNECTED IF HEAT PUMP HAS A FAULT TERMINAL.
2: SOME HEAT PUMPS USE B RATHER THAN O FOR REVERSING VALVE.
3: THE HEAT PUMP AND FURNACE HAVE SEPARATE BOARDS. THEY ARE SHOWN TOGETHER HERE TO SIMPLIFY THIS DIAGRAM. W IS FROM THE FURNACE BOARD.
4: C7089U1006 WIRED OUTDOOR SENSOR CAN BE USED FOR BALANCE POINT IF DESIRED.
5: IMPORTANT: DO NOT CONNECT ANY WIRE TO W FOR HEAT PUMP APPLICATIONS! THIS CAN CAUSE HEAT TO RUN CONTINUOUSLY.
Dual Fuel 3H/2C: Heat Pump
Compatible models: TH2320 models only
1: L ONLY CONNECTED IF HEAT PUMP HAS A FAULT TERMINAL.
2: SOME HEAT PUMPS USE B RATHER THAN O FOR REVERSING VALVE.
3: THE HEAT PUMP AND FURNACE HAVE SEPARATE BOARDS. THEY ARE SHOWN TOGETHER HERE TO SIMPLIFY THIS DIAGRAM. W IS FROM THE FURNACE BOARD.
4: C7089U1006 WIRED OUTDOOR SENSOR CAN BE USED FOR BALANCE POINT IF DESIRED.
5: IMPORTANT: DO NOT CONNECT ANY WIRE TO W FOR HEAT PUMP APPLICATIONS! THIS CAN CAUSE HEAT TO RUN CONTINUOUSLY.